TY - GEN
T1 - Kinematic Analysis of a 3-RPS Parallel Mechanism for Passive Rehabilitation of Sports-Related Ankle Sprains
AU - Gonzalez-Dancourt, Dario
AU - Huaytalla-Pariona, Jaime
AU - Calderon-Mendez, Piero
AU - Huamanchahua, Deyby
N1 - Publisher Copyright:
© 2025 IEEE.
PY - 2025
Y1 - 2025
N2 - Ankle sprains are common among athletes, especially in ball sports, and often require targeted rehabilitation to restore joint mobility. This article presents the design and evaluation of a 3-RPS type parallel mechanism developed for the passive rehabilitation of lateral ankle sprains. The system replicates natural ankle movements using inverse kinematic models based on geometric methods and screw theory. To solve the forward kinematics, three numerical strategies were tested: gradient descent, gradient descent with momentum, and Newton-Raphson, with the latter being the most efficient. Workspace analysis confirmed that the mechanism covers the physiological ranges for dorsiflexion-plantarflexion (30° to -20°) and eversion-inversion (20° to -10 °), with vertical displacements ranging from 0.2044 m to 0.3046 m. Both positional and orientational workspaces were analyzed to ensure complete therapeutic coverage. A singularity analysis identified twelve critical configurations, all of which are outside the effective operating range. Structurally, the device is compact and lightweight (≤ 3.5 kg), ensuring portability and ease of use in clinical and sports environments. Its precision, stability, and ability to generate controlled, repeatable ankle movements make it a valuable tool for early-stage rehabilitation, promoting functional recovery in injured athletes.
AB - Ankle sprains are common among athletes, especially in ball sports, and often require targeted rehabilitation to restore joint mobility. This article presents the design and evaluation of a 3-RPS type parallel mechanism developed for the passive rehabilitation of lateral ankle sprains. The system replicates natural ankle movements using inverse kinematic models based on geometric methods and screw theory. To solve the forward kinematics, three numerical strategies were tested: gradient descent, gradient descent with momentum, and Newton-Raphson, with the latter being the most efficient. Workspace analysis confirmed that the mechanism covers the physiological ranges for dorsiflexion-plantarflexion (30° to -20°) and eversion-inversion (20° to -10 °), with vertical displacements ranging from 0.2044 m to 0.3046 m. Both positional and orientational workspaces were analyzed to ensure complete therapeutic coverage. A singularity analysis identified twelve critical configurations, all of which are outside the effective operating range. Structurally, the device is compact and lightweight (≤ 3.5 kg), ensuring portability and ease of use in clinical and sports environments. Its precision, stability, and ability to generate controlled, repeatable ankle movements make it a valuable tool for early-stage rehabilitation, promoting functional recovery in injured athletes.
KW - 3-RPS parallel mechanism
KW - Passive rehabilitation
KW - ankle sprain
KW - kinematics analysis
UR - https://www.scopus.com/pages/publications/105033336226
U2 - 10.1109/C366505.2025.11340556
DO - 10.1109/C366505.2025.11340556
M3 - Conference contribution
AN - SCOPUS:105033336226
T3 - C3 2025 - IEEE Colombian Caribbean Conference
BT - C3 2025 - IEEE Colombian Caribbean Conference
A2 - Gomez, Yesica Beltran
A2 - Mendoza, Paul Sanmartin
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2025 IEEE Colombian Caribbean Conference, C3 2025
Y2 - 17 September 2025 through 20 September 2025
ER -