TY - JOUR
T1 - Evaluation of the behavior and ultimate capacity of unbonded monostrand-anchorage systems under concentric and eccentric inelastic cyclic loading
AU - Bedriñana, Luis Alberto
AU - Zhang, Kaiwei
AU - Nishiyama, Minehiro
N1 - Publisher Copyright:
© 2018 Elsevier Ltd
PY - 2018/12/1
Y1 - 2018/12/1
N2 - Unbonded post-tensioning (PT) monostrands have traditionally been used in buildings to sustain monotonic loads on members subjected mainly to gravity loads. As a result, most of the technical information on commercially available unbonded PT anchorage systems focused only on applications for gravity-loaded members. Despite the recent experimental research efforts on the behavior of PT anchorages under earthquake-simulated demands, this information has not been well quantified in design documentation. Consequently, further research is needed on unbonded PT anchorages for their use in members subjected to seismic loads. This paper presents the results of a comprehensive experimental evaluation on the ultimate capacity of monostrand anchorages subjected to high-amplitude concentric and eccentric cyclic loads. In addition, this paper addresses the influence of anchorage type, loading patterns and strand size on the ultimate deformation capacity of these anchorages. Specimens consisted of monostrands assembled with anchorages at both ends. Two types of anchorages were tested. Moreover, seven-wire, uncoated, low-relaxation PT monostrands in two sizes were considered. Several cyclic loading conditions were applied, in order to evaluate the behavior of anchorages under different scenarios. The ultimate capacity of the specimens was dominated by a premature fracture of one or few wires inside the wedges and two types of wire fractures were recognized: (1) with little reduction in the wire cross-sectional area and (2) with a notable reduction in the wire cross-sectional area prior the fracture. It was also observed that increased number of wire fractures correlated with larger strain capacity in some specimens. In addition, it was observed that eccentric loads reduced the strain capacity by about 18% for eccentricities of 6% in some cases. The fracture of the specimens occurred at relatively small strains, with values as low as 1.4%. Therefore, strains in unbonded post-tensioned strands should be limited to about 1.0% when designing for seismic loads. Furthermore, an analytical model was proposed to evaluate the influence of anchorages in unbonded post-tensioning precast structures.
AB - Unbonded post-tensioning (PT) monostrands have traditionally been used in buildings to sustain monotonic loads on members subjected mainly to gravity loads. As a result, most of the technical information on commercially available unbonded PT anchorage systems focused only on applications for gravity-loaded members. Despite the recent experimental research efforts on the behavior of PT anchorages under earthquake-simulated demands, this information has not been well quantified in design documentation. Consequently, further research is needed on unbonded PT anchorages for their use in members subjected to seismic loads. This paper presents the results of a comprehensive experimental evaluation on the ultimate capacity of monostrand anchorages subjected to high-amplitude concentric and eccentric cyclic loads. In addition, this paper addresses the influence of anchorage type, loading patterns and strand size on the ultimate deformation capacity of these anchorages. Specimens consisted of monostrands assembled with anchorages at both ends. Two types of anchorages were tested. Moreover, seven-wire, uncoated, low-relaxation PT monostrands in two sizes were considered. Several cyclic loading conditions were applied, in order to evaluate the behavior of anchorages under different scenarios. The ultimate capacity of the specimens was dominated by a premature fracture of one or few wires inside the wedges and two types of wire fractures were recognized: (1) with little reduction in the wire cross-sectional area and (2) with a notable reduction in the wire cross-sectional area prior the fracture. It was also observed that increased number of wire fractures correlated with larger strain capacity in some specimens. In addition, it was observed that eccentric loads reduced the strain capacity by about 18% for eccentricities of 6% in some cases. The fracture of the specimens occurred at relatively small strains, with values as low as 1.4%. Therefore, strains in unbonded post-tensioned strands should be limited to about 1.0% when designing for seismic loads. Furthermore, an analytical model was proposed to evaluate the influence of anchorages in unbonded post-tensioning precast structures.
KW - Anchorages
KW - Cyclic loading
KW - Eccentric load
KW - Inelastic strain
KW - Monostrand
KW - Post-tensioning
KW - Self-centering system
KW - Strain capacity
UR - http://www.scopus.com/inward/record.url?scp=85053814008&partnerID=8YFLogxK
U2 - 10.1016/j.engstruct.2018.09.036
DO - 10.1016/j.engstruct.2018.09.036
M3 - Article
AN - SCOPUS:85053814008
SN - 0141-0296
VL - 176
SP - 632
EP - 651
JO - Engineering Structures
JF - Engineering Structures
ER -