TY - JOUR
T1 - Contribution of the light-collection non-uniformity to the energy resolution for the spaghetti-type calorimeter modules
AU - Guliaeva, V.
AU - Kholodenko, S.
AU - Shmanin, E.
AU - Anokhina, A.
N1 - Publisher Copyright:
© 2025 IOP Publishing Ltd and Sissa Medialab. All rights, including for text and data mining, AI training, and similar technologies, are reserved.
PY - 2025/4/1
Y1 - 2025/4/1
N2 - Abstract Spaghetti-type calorimeters (SpaCal) are being considered as a potential solution for experiments at the High-Luminosity Large Hadron Collider (HL-LHC). SpaCal modules consist of an absorber block with a matrix of holes filled with scintillating fibres. This geometry offers a flexible granularity. However, the total number of scintillating fibres per channel could exceed the available photocathode surface area, necessitating a light guide to efficiently collect and register the scintillating light from the scintillating fibres to a photomultiplier. The non-uniformities in the light collection would impact the energy resolution of the detector. In this study, the impact of the light collection non-uniformity on the energy resolution is estimated for the various geometries of light guides using optical simulations (GEANT4 simulation with optical photons). The study performed assumed a SpaCal prototype with 30× 30 mm2 cell size and photomultipliers featuring realistic entrance window shapes and sizes, and explores different light guide designs.
AB - Abstract Spaghetti-type calorimeters (SpaCal) are being considered as a potential solution for experiments at the High-Luminosity Large Hadron Collider (HL-LHC). SpaCal modules consist of an absorber block with a matrix of holes filled with scintillating fibres. This geometry offers a flexible granularity. However, the total number of scintillating fibres per channel could exceed the available photocathode surface area, necessitating a light guide to efficiently collect and register the scintillating light from the scintillating fibres to a photomultiplier. The non-uniformities in the light collection would impact the energy resolution of the detector. In this study, the impact of the light collection non-uniformity on the energy resolution is estimated for the various geometries of light guides using optical simulations (GEANT4 simulation with optical photons). The study performed assumed a SpaCal prototype with 30× 30 mm2 cell size and photomultipliers featuring realistic entrance window shapes and sizes, and explores different light guide designs.
KW - Calorimeter methods
KW - Calorimeters
KW - Detector modelling and simulations I (interaction of radiation with matter, interaction of photons with matter, interaction of hadrons with matter, etc)
KW - Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators)
UR - https://www.scopus.com/pages/publications/105003036906
U2 - 10.1088/1748-0221/20/04/P04018
DO - 10.1088/1748-0221/20/04/P04018
M3 - Article
AN - SCOPUS:105003036906
SN - 1748-0221
VL - 20
JO - Journal of Instrumentation
JF - Journal of Instrumentation
IS - 4
M1 - P04018
ER -